A medical air mattress is more than just an inflatable sleeping surface. It's a powered support system that uses both a structured air cell mattress and a control pump to allow the support pattern to be changed at various times. The dynamic movement of the mattress assists in distributing the user's weight when they are lying down for long periods of time.
The Senyang T08 medical air mattress works in conjunction with the P06B digital pump to provide users with a complete alternating pressure system. The Senyang T08 medical air mattress has a 9-inch thick profile and utilizes a three-layer design. The P06B digital pump allows for adjustable cycle times, adjustable pressure settings, several operational modes, alarm functions, and remote control capabilities.
The end result is a highly customizable medical mattress system, which combines deep air-cell support, user-friendly controls, and multiple material choices on a single platform.
A standard air mattress has either just one or only a couple of very large air chambers, and once it is filled with air it will remain under the same amount of pressure. On the other hand, the T08 features a number of individually controlled groups of small tubular air cells. When the P06B varies the airflow between those groups of cells, the areas that support the user's body will vary throughout the cycle.
Instead of providing a static support pattern by continuously loading the same area, this alternating motion creates a dynamic support pattern. This means that the mattress stays inflated and provides support as it would during regular usage. Rather than repeatedly emptying the entire surface, each group of air cells alters its relationship to the other groups of air cells.
The T08 has another advantage over a simple bubble overlay. It is a full-fledged medical air mattress system that includes a much deeper support surface than a typical bubble overlay and an additional layer at the base.

The P06B is the control unit which both provides power to and operates the T08 mattress. The P06B contains digital displays along with direct controls and a remote control so that the operating condition can be monitored and changed via several different means than just one mechanical dial.
Alternating mode changes airflow between the active cell groups. Four cycle choices are available: 6, 9, 12 and 25 minutes. This allows the system configuration to be adapted to different operating requirements.
Static mode provides users with an alternative support option that allows the support surface to remain in a fixed position, rather than continuing its regular alternating cycle. Users may choose static mode if they require a consistent support surface for a specific care activity.
AutoFirm provides a firmer mattress surface for short-term care tasks. It is a functional operating mode rather than the default setting for continuous use.
Adjusting the seating mode provides a more vertical orientation, which changes how much you weigh on each part of your body and how your weight is distributed across the surface that supports you.
After you select the operating parameters, panel lock will help ensure that you do not accidentally alter those parameters. Remote control allows users to easily adjust typical settings on their pumps, rather than having to make each and every adjustment using the controls located on the pump itself.
The sound alarm draws attention to a pump or pressure condition that needs checking. It monitors the mattress system, not the user's medical or skin condition.
The P06B has two pumps for providing air flow from 8 to 10 liters per minute. The aluminum motor housing provides cooling and is designed with an anti-vibration design for stability. It is also rated at a noise level that will not exceed 20 decibels when operated as specified by the manufacturer.
P06B technical specifications:
Cycle time and pressure are different settings. The cycle determines how quickly the alternating sequence repeats, while pressure affects the level of support supplied by the system.

The T08 is designed around three functional layers rather than a single set of air cells.
The top and second layers contain the active air cells. In the current T08 configuration, these cells can be arranged in A-B or A-B-C alternating groups. The P06B controls the airflow sequence, changing the support distribution across the mattress.
The tubular cell shape allows the mattress to form a deep, responsive surface. Each cell contributes to the overall body support while participating in the selected alternating pattern.
The bottom layer remains static during normal alternating operation. It provides a separate underlying air-supported base beneath the active layers. This gives the T08 a three-layer profile and distinguishes it from single-layer medical air overlays.
The pillow section remains static to provide consistent support near the head. It works independently from the alternating groups across the main body area.
The combination of alternating upper sections, a static lower layer and a static pillow area creates a clearly organised support system. Each part has a different role instead of every cell performing the same movement.

The standard T08 configuration is designed around a full-length medical mattress surface:
The 42-inch and 48-inch widths are separate mattress configurations, not an adjustment built into one standard mattress. Mattress width, material, air circuit and pump electrical version should be selected as a complete product specification.

The T08 can be produced with Nylon TPU or pure TPU air cells.
Nylon TPU is created by combining a woven nylon fabric with a TPU coating. The resulting material is a flexible, cellular structure that has the added strength of textile reinforcing. Pure TPU provides a soft, elastomeric air-cell material that provides excellent sealing properties. Depending on the product specifications and intended audience for the product, either option may be chosen.
The cell layer of the mattress has a 2-way stretch PU cover with a zipper closure. The cover provides a smooth contact surface and can be ordered with waterproof properties. A flame retardant cover can also be ordered as an option.
The bottom of the mattress is made from Dacron PVC. This will allow for the different layers to have their own individual functions (i.e. to be structurally supportive, etc.).
In addition, some of the T08 configurations feature ventilated bladders which will allow air to circulate around the mattress surface. This is part of the mattress design and is not related to the pump-controlled alternate cycles.
The T08 features a CPR release which can quickly deflate the mattress to provide a hard surface for emergency medical treatment. The function of this CPR release is completely independent of the regular deflation/inflation functions of the T08, and also from the cycle setting functions of the P06B.
The T08 uses the release in the mattress structure to provide an obvious emergency function that doesn't use standard pump controls to deflate quickly.

The T08 provides options for users to select from when choosing their mattress, however, it remains true to the three-layer mattress system that has been used previously.
The 32-36 inch configuration will fit many standard hospital bed sizes. However, there are also 42 inch and 48 inch options that allow for additional supporting area. When evaluating which configuration best meets your needs, you need to look at both the usable bed platform and the total height of the mattress.
Pure TPU is an alternative that is soft and has elasticity. Nylon TPU offers a way to provide reinforcement to textiles with a coating that will allow for air retention. The decision of which option to select may depend upon the product's positioning, what types of materials are preferred, and what is required by the market.
The PU cover provides the external contact surface. Waterproof performance and an optional flame-retardant specification can be selected according to the required product configuration.
The P06B electrical supply, fuse, plug, and product label must be compliant with the requirements of the intended market. Additionally, the mattress air circuit and connector configuration should be identified in conjunction with the pump.
The T08 and P06B systems are capable of providing pressure-care support for patients in many different types of healthcare facilities including hospitals, nursing homes, rehabilitation centers, long-term care facilities and home-based care with appropriate support services. The benefits of this system are due to the use of a deep air cell surface and an electronic control system, rather than the product being limited to only one type of facility.
The mattress will help with pressure redistribution and the person's comfort while on long-term bed rest. This is only one component of a larger overall care plan. Therefore, it is important to remember that this does not substitute for each individual's assessment, turning/repositioning schedule, checking of the skin, nor does it provide a replacement for the professional medical opinion.
Since 1999, Senyang has specialized in pressure-care products. We design medical air mattresses along with corresponding control pumps, enabling us to manage mattress design, air circuit, connector, control unit, and available materials as a unified system.
This T08 and P06B combination is intended for those customers that require an advanced form of an air overlay. In addition to a nine inch, three layer mattress, it provides users with multiple options for width and materials, as well as digital pumps and remote controls. There are also several different modes of operation available through this single configurable system.
We are able to provide you with the opportunity to review your choice of materials, widths, electric versions, product labeling, logos and packaging as part of an agreed-upon project with distributors, healthcare brand owners and care equipment manufacturers.
The T08 has a 9-inch, three-layer construction and is positioned as a full medical air mattress system rather than a thin bubble overlay.
Both belong to the P06 pump series and offer digital displays and multiple operating functions. P06B uses its own control interface and remote, while P06C is the touch-panel version. This page describes T08 with P06B.
No. The upper and second layers provide the alternating support pattern, while the bottom layer and pillow area remain static.
They are alternating cycle options. They describe how long the selected cycle takes to repeat, not how long the mattress takes to inflate from empty.
No. The alarm relates to the mattress and pump system. It does not assess skin condition or provide a medical diagnosis.
Yes. In addition to the standard 32–36-inch width, T08 is available in 42-inch and 48-inch configurations.
Yes. Air-cell options include Nylon TPU and pure TPU, while the PU cover can be specified with waterproof performance and an optional flame-retardant requirement.
Please provide the required mattress width, air-cell material, cover requirement, quantity, destination market, electrical version and any branding or packaging needs.
If you need a medical air mattress with deeper support, digital controls and multiple operating modes, the T08 and P06B provide a clearly defined platform with meaningful configuration choices.
Contact Senyang with your mattress width, material preference, electrical requirement and quantity. We will help you configure the T08 medical air mattress and P06B digital pump for your product range or care project.