At Senyang, we designed the B01 alternating pressure mattress for hospital bed use as a straightforward pressure-care system for patients who spend extended periods in bed. The 130-bubble PVC pad works with the TKS2012 pump to create a repeating inflation and deflation pattern across the support surface.
The system combines adjustable air pressure, a 12-minute alternating cycle, secure 400 mm end flaps, and a compact pump. It is easy to introduce into hospital wards, nursing environments, and home-care product ranges where a dependable entry-level alternating surface is required.

The B01 pad contains 130 individual bubbles arranged across the mattress surface. As the TKS2012 pump alternates airflow, different areas inflate and deflate in sequence, changing where support is concentrated beneath the user.
This dynamic action supports pressure redistribution during long-term bed care. B01 is a pressure-care aid and should be used together with the facility's repositioning schedule, skin assessment, clinical judgement, and other prescribed care measures.
The inflated mattress measures 2000 x 900 x 70 mm, making it suitable for compatible hospital-bed platforms. Two 400 mm end flaps help hold the pad in position over the underlying mattress and reduce unwanted movement during routine use.
Before installation, confirm the bed platform dimensions, side-rail clearance, backrest articulation, mattress condition, and safe routing for the air hose. The pad should lie flat without sharp folds or trapped tubing.

The TKS2012 pump provides a 70-130 mmHg pressure range so the support level can be adjusted within the system's specified operating range. Selection should follow the product instructions and the user's assessed weight, comfort, posture, and care plan.
Air output is 6 L/min, supporting inflation of the bubble pad and continued alternating operation after setup.
The pump follows a 12-minute alternating cycle. Its uncomplicated control layout helps caregivers set the required pressure without navigating advanced menus or multiple therapy programs.
Power options are available for 220 V / 50 Hz or 110 V / 60 Hz markets. The pump uses 12 VA, includes a 0.5 A fuse, and has a net weight of 0.78 kg.
| Specification | B01 System |
|---|---|
| Mattress model | B01 |
| Pump model | TKS2012 |
| Mattress dimensions | 2000 x 900 x 70 mm |
| Bubble count | 130 |
| End flaps | 400 mm |
| Materiale | PVC |
| PVC thickness options | 0.3 mm or 0.4 mm |
| Mattress net weight | 2 kg |
| Maximum user weight | 135 kg |
| Included mattress accessories | Repair kit and hose |
| Pump power | 220 V / 50 Hz or 110 V / 60 Hz |
| Air output | 6 L/min |
| Campo di pressione | 70-130 mmHg |
| Cycle time | 12 minutes |
| Power consumption | 12 VA |
| Fuse | 0.5 A |
| Pump net weight | 0.78 kg |
| Conformità | FDA, CE, EU MDR; manufactured under an ISO 13485 quality management system |

The B01 mattress is manufactured from PVC and is available with 0.3 mm or 0.4 mm material thickness. This gives buyers a clear material choice for different channel, durability, and price-positioning requirements.
The mattress weighs 2 kg and supports a maximum user weight of 135 kg. A hose and repair kit are included with the mattress configuration, supporting setup and basic product maintenance.
Place the B01 over the existing hospital-bed mattress with the bubble surface facing upward, then secure the end flaps. Connect the hose firmly to the pad and pump, position the pump where its air intake remains clear, and route the hose away from moving bed parts.
Allow the pad to inflate according to the instructions before use. During routine care, check the pump power, hose connections, pad position, pressure setting, user comfort, skin condition, and any signs of air leakage or material damage.
Disconnect the power before cleaning the pump. Follow the supplied cleaning instructions for the PVC pad and pump housing, avoid abrasive tools or unapproved chemicals, and prevent liquid from entering the pump.
Dry every component fully before reuse. For storage or transport, disconnect the hose, deflate the mattress gently, avoid tight creases, and keep the pad away from sharp objects, high heat, and heavy items that could damage the bubbles.
We manufacture B01 alternating pressure mattress systems for hospital, long-term care, home-care, distribution, and private-label product ranges. The product is available with FDA, CE, and EU MDR compliance and is manufactured under our ISO 13485 quality management system.
Share your destination market, voltage, required PVC thickness, order quantity, branding, packaging, manual language, and documentation requirements. Our team will confirm the available B01 and TKS2012 configuration and prepare a project quotation.
The TKS2012 pump alternates airflow through the B01 bubble pad on a 12-minute cycle, changing the support pattern across 130 air bubbles.
The mattress measures 2000 x 900 x 70 mm. Confirm the specific bed platform, rails, articulation, and underlying mattress before installation.
The specified maximum user weight is 135 kg.
The featured system uses the TKS2012 pump with 70-130 mmHg adjustment, 6 L/min output, and a 12-minute cycle.
The B01 mattress is available in 0.3 mm and 0.4 mm PVC configurations.
The mattress specification includes a hose and repair kit. Confirm the complete order-specific accessory list with Senyang.
Share your target market, voltage, PVC thickness, order quantity, branding, packaging, and documentation requirements. Our team will help you confirm the B01 system and quotation.