Choosing a manufacturer of medical air mattress systems requires much more than simply comparing prices of individual mattresses. You will receive a complete system with the mattress, air pump, hose connections, electrical version of the system, packaging and all related product documentation delivered to you in a single consistent package. Senyang are a manufacturer of medical air mattress systems and pumps for distributors, health care brands and projects that require repeatable product configuration rather than isolated components.
The above page displays our B01 alternating air mattress with the TKS2012 pump. Our B01 offers a bubble style air support system, while our TKS2012 provides variable alternating air flow. Combined, these two units provide an effective, practical medical air mattress system designed to assist with long term bed rest and pressure management.
The B01 mattress consists of multiple air sections that function as two alternating groups. At the end of every cycle, the TKS2012 changes how the air flows through both groups. This allows the mattress to alternate providing firmer support in different regions rather than staying with a single set pressure pattern.
This alternating action is the central function of the system. As the active support areas change through each cycle, the B01 and TKS2012 provide a consistent pressure-redistribution pattern for extended bed-rest applications.
The combination of B01 mattress, TKS2012 pump and connection hose is treated by us as a complete set. Prior to manufacturing, we verify the compatibility of the pump's output, connector design, air circuit of the mattress, and power supply. Confirming these elements as one system helps maintain stable airflow, compatible connections and consistent electrical specifications across samples and bulk orders.


The B01 features an inflatable bubble-type support surface that can be attached to the top of your existing mattress. Each of the connected air groups provide alternating pressure throughout the entire surface of the overlay. Additionally, the overlay includes end flap attachments which allow you to secure it to your underlying bed mattress. This compact design is ideal for applications where you want a simple, cost-effective alternating system.
The B01 features 130 air bubbles and measures 2000 x 900 x 70 mm when inflated. Its 400 mm end flaps allow for positioning the overlay on top of the underlying mattress. There are two options for the thickness of the PVC used to make the mattress (0.3 mm or 0.4 mm). The mattress' reference net weight is 2 kg with a stated weight capacity of 135 kg. Both a connecting hose and repair kit come standard with each purchase.
Medical grade PVC material from Taiwan Nanya company, durable and high quality.

Pressure relief mattresses offer numerous advantages, making them essential in medical and care settings:


Senyang was founded in 1999, specializing in medical rehabilitation and patient care equipment. Senyang manufactures the most important components of medical air mattresses. These include: material preparation, high frequency welding, pump assembly, sewing, printing, inspection, and packaging.
We have the ability to control both the manufacturing of mattresses and pumps. This enables us to address several of the most common reasons why complete systems fail, including weak welds, air leaks, unstable pump outputs, mismatched connections, incorrect voltage labeling, and inconsistent accessories. In addition to this, it allows OEM customers to deal with a single team for all aspects of their physical products, electrical units, packaging, and artwork.
Our manufacturing resources include a 24,000 m² facility, dedicated production lines and in-house testing and quality-inspection processes. After the product configuration, materials, packaging, quantity and order schedule are confirmed, we prepare a project-specific production and delivery plan for the customer.
Quality assurance starts prior to the completion of the packing process. The quality of incoming materials, how well the welded parts of the mattress are assembled, if air is retained in the mattress, if the pump functions as expected, if the electrical components are wired correctly, if the hoses connect properly, if accessories are available and correctly identified, if labels are applied correctly to the product and the packaging, will determine if the completed system meets the quality standards of the approved sample.
For B01+TKS2012 projects, the production and inspection plan can cover:
For each project, we match the available regulatory and technical documents to the destination market and the exact B01 and TKS2012 configuration being supplied. This gives customers a clear document scope for model review, private-label preparation and market registration requirements
OEM and private-label options include: We record the confirmed material, air circuit, electrical parts, artwork, labels, accessories and packaging in the project specification. When a technical element changes, our team updates the sample and document review so the new configuration can be approved before bulk production.
Available project discussions may include:
Customization is based on the approval of a specification. If you are changing a material, air circuit, electrical part or intended claim, it may be necessary to have another sample reviewed and documents checked, just because you have the artwork approved, doesn't mean that will suffice when making a technical product change.
A strong wholesale program begins with an accurately represented sample. Prior to producing the sample, we verify the B01 mattress model, the TKS2012 electrical specification, the product packaging contents, brand-related specifications, and the potential target consumer. The resulting sample allows the customer to review the mattress, pump, electrical version, accessories, branding and packaging as one complete saleable system.
Once approved, the sample and specifications are the standard for manufacturing. Each time an order is repeated, the same controlled file (model number, material, color, pump label, electrical cord, instruction booklet, accessories, carton markings) will be used. Changes to the files are documented and reviewed prior to the implementation of the changes into the production process.
The process described here will be most beneficial to distributors developing their product lines. This system can help eliminate some of the unknowns that exist between a quote, sample and future orders. In addition, this system can provide clarity as to what each adjustment to the order will do to affect costs, delivery times and required paperwork.
The fastest way to receive an accurate proposal is to describe the required system, not only ask for a unit price. Please include:
If some specifications are not yet decided, we can start from the intended market and product position, then confirm which B01 configuration should be sampled.
Working directly with Senyang gives buyers one manufacturing team for the mattress, pump, electrical version, materials, dimensions, accessories and packaging. We define these elements in the B01 and TKS2012 specification so the quotation, sample, bulk order and repeat order follow the same product configuration. Buyers receive a clear system scope, a physical sample for approval and controlled production files for future orders. This simplifies coordination between the brand owner, importer and factory while making configuration and cost changes easier to track.
We are a manufacturer based in Xiamen, China, established in 1999. Senyang produces medical air mattresses, matching pumps and other rehabilitation
Every quote must make clear if you are purchasing the whole system or just the mattress. The standard configuration includes the B01 Mattress, the TKS2012 Pump, the connecting hose and the repair kit.
Yes. We can quote the B01 mattress alone or a complete B01 and TKS2012 system. Each quotation lists the included mattress, pump, hose, repair kit, electrical version and packaging so buyers can compare the required supply scope clearly.
Yes. The TKS2012 supports 110V/60Hz or 220V/50Hz configurations. We match the voltage, plug, electrical label and related specification to the destination country when confirming the order.
Yes. Logo placement, pump labels, control-panel artwork, packaging and manual language can be discussed for OEM projects after the base product configuration is confirmed.
Approve the complete sample together with the written specification, artwork, labels, accessories and packaging. The approved version should remain the reference for bulk inspection and repeat orders.
Available documents depend on the exact model, configuration and destination market. Tell us which documents are required so they can be checked against the supplied B01+TKS2012 version.
Send us the destination, voltage, mattress requirements, quantity, required package contents, branding needs and document list. We will prepare a B01 mattress-only or B01 and TKS2012 system quotation with the selected configuration clearly itemised.
The B01+TKS2012 is a practical starting point for distributors and healthcare brands that need an alternating bubble mattress system with adjustable pump control. More importantly, it can be defined as a repeatable product: one mattress model, one matched pump, one approved accessory list and one controlled package.
Contact Senyang with your market, required quantity and customization plan. We will help confirm the B01 mattress specification, TKS2012 electrical version, sample scope and bulk-production requirements for your medical air mattress project.